Xiensolar 8kW 48V Hybrid Inverter UPS | IP66 Rated
Descrizione
Xiensolar HCC-SM-EP-D Series: The Ultimate 48V Hybrid Inverter UPS
Uninterrupted Power. Industrial-Grade Durability. Smart Energy Management.
In an era of unpredictable grid stability and rising energy costs, the Xiensolar HCC-SM-EP-D Series stands as your fortress of energy security. Engineered for high-performance residential and light commercial applications, this versatile system acts as both a high-efficiency solar manager and a powerful 48V hybrid inverter UPS (Uninterruptible Power Supply).
Available in 5kW, 6kW, and 8kW configurations, the EP-D series is designed to seamlessly switch between solar, battery, and grid power, ensuring your critical loads never go dark. With a rugged IP66 design and massive surge capability, it is built to perform where others fail.
Why the Xiensolar EP-D Series is the Smart Choice
Unlike standard inverters that simply convert DC to AC, the Xiensolar EP-D is an intelligent energy hub. It maximizes self-consumption during the day and acts as a robust backup guardian at night or during outages.
1. True UPS Capability with 2X Surge Power
The defining feature of a reliable 48V hybrid inverter UPS is its ability to handle “inrush current”—the spike of power needed to start heavy appliances like well pumps, air conditioners, and refrigerators.
Instant Switchover: When the grid fails, the Xiensolar inverter switches to battery mode in milliseconds, keeping your electronics running without interruption.
Double the Power: The system can deliver 2 times its rated power for 10 seconds. For the 8kW model, this means a massive 16,000W surge capacity, allowing you to start heavy inductive loads that would trip lesser inverters.
2. Optimized for 48V Low Voltage Batteries
Safety and affordability are key. We utilize a 48V low-voltage battery architecture (40V-60V range), which is significantly safer for residential installation than high-voltage systems.
Universal Compatibility: Whether you prefer the longevity of Lithium-ion or the cost-effectiveness of Lead-acid, our inverter supports both.
Smart BMS Communication: Features “Self-adaption to BMS” via CAN/RS485, ensuring your Lithium batteries are charged precisely to their specifications for maximum lifespan.
Ultra-Fast Charging: The 8kW model boasts a market-leading Max Charging Current of 190A, allowing you to top up large battery banks quickly during limited sun hours or off-peak grid windows.
3. IP66: Built for the Harshest Elements
Don’t hide your inverter in the garage. The Xiensolar EP-D Series carries an IP66 Ingress Protection rating.
Dust Tight & Water Resistant: Superior to the standard IP65, IP66 means the unit is fully protected against powerful water jets and heavy seas. It is perfectly suited for outdoor installation in humid, dusty, or coastal environments.
Smart Cooling System: Equipped with active smart cooling technology, the system effectively manages heat dissipation even under heavy loads (Noise <50dB), ensuring component longevity and consistent performance in hot climates.
4. Future-Ready PV Input
Solar panels are getting bigger and more powerful. Your inverter needs to keep up.
High Current Support: With a PV input current of up to 26A+26A (8kW model), this inverter is fully compatible with the latest 182mm and 210mm high-power solar modules.
Dual MPPT Trackers: Two independent Maximum Power Point Trackers allow you to install panels on different roof facets (e.g., East and West) to capture sunlight throughout the entire day.
Technical Architecture & Safety
At Xiensolar, we prioritize safety above all. The EP-D 48V hybrid inverter UPS integrates comprehensive protection mechanisms, reducing the need for external safety boxes and lowering installation costs.
Integrated AFCI (Arc Fault Circuit Interrupter): Detects dangerous electrical arcs in the solar array and shuts down the system to prevent fires.
Type II Surge Protection: Both DC (Solar) and AC (Grid) sides are protected against voltage spikes and lightning induced surges.
Grid Safety: Compliant with strict grid regulations (IEC 61727/62116, EN50549-1), featuring Anti-islanding protection to ensure the safety of utility workers.
Model Comparison: Choose Your Power
Select the right size for your energy needs. All models feature the same robust IP66 build and smart monitoring capabilities.
| Category | Model Parameters | 5kW Model | HCC05-SM-0060H-EP-D | HCC05-SM-0080H-EP-D |
|---|---|---|---|---|
| Battery Input Data | Battery Type | Lead-acid or Li-Ion | Lead-acid or Li-Ion | Lead-acid or Li-Ion |
| Battery Voltage Range(V) | 40-60 | 40-60 | 40-60 | |
| Max. Charging Current(A) | 120 | 135 | 190 | |
| Max. Discharging Current(A) | 120 | 135 | 190 | |
| Charging Curve | 3 Stages/Equalization | 3 Stages/Equalization | 3 Stages/Equalization | |
| External Temperature Sensor | Yes | Yes | Yes | |
| Charging Strategy for Li-Ion Battery | Self-adaption to BMS | Self-adaption to BMS | Self-adaption to BMS | |
| PV String Input Data | Max. DC Input Power(W) | 6500 | 7800 | 10400 |
| PV Input Voltage(V) | 370V (125V-500V) | 370V (125V-500V) | 370V (125V-500V) | |
| MPPT Range(V) | 150-425V | 150-425V | 150-425V | |
| Full Load DC Voltage Range | 300-425V | 300-425V | 300-425V | |
| Start-up Voltage(V) | 125V | 125V | 125V | |
| PV Input Current(A) | 18+18 | 18+18 | 26+26 | |
| Max. PV Isc(A) | 27+27 | 27+27 | 34+34 | |
| No. of MPP Trackers | 2 | 2 | 2 | |
| No. of Strings Per MPPT Tracker | 1+1 | 1+1 | 1+1 | |
| AC Input/Output Data | Rated AC Output and UPS Power(W) | 5000 | 6000 | 8000 |
| Max. AC Output Power(W) | 5500 | 6600 | 8800 | |
| Peak Power (off grid) | 2 times of rated power, 10S | 2 times of rated power, 10S | 2 times of rated power, 10S | |
| AC Input/Output Rated Current(A) | 22.8/21.8 | 27.3/26.1 | 36.4/34.8 | |
| Max. AC Input/Output Current(A) | 25/24 | 30/28.7 | 40/38.3 | |
| Max. Continuous AC Passthrough(A) | 35 | 40 | 50 | |
| Power Factor | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | |
| Output Frequency and Voltage | 50/60Hz; 220/230Vac | 50/60Hz; 220/230Vac | 50/60Hz; 220/230Vac | |
| Grid Type | Single Phase | Single Phase | Single Phase | |
| Total Harmonic Distortion (THDi) | <3% (of nominal power) | <3% (of nominal power) | <3% (of nominal power) | |
| DC Current Injection | <0.5% In | <0.5% In | <0.5% In | |
| Efficienza | Max. Efficiency | 97.60% | 97.60% | 97.60% |
| Euro Efficiency | 96.50% | 96.50% | 96.50% | |
| MPPT Efficiency | >99% | >99% | >99% | |
| Protection | PV Arc Fault Detection | Integrated | Integrated | Integrated |
| PV Input Lightning Protection | Integrated | Integrated | Integrated | |
| Anti-islanding Protection | Integrated | Integrated | Integrated | |
| PV String Input Reverse Polarity Protection | Integrated | Integrated | Integrated | |
| Insulation Resistor Detection | Integrated | Integrated | Integrated | |
| Residual Current Monitoring Unit | Integrated | Integrated | Integrated | |
| Output Over Current Protection | Integrated | Integrated | Integrated | |
| Output Shorted Protection | Integrated | Integrated | Integrated | |
| Surge Protection | DC Type II / AC Type II | DC Type II / AC Type II | DC Type II / AC Type II | |
| Over Voltage Category | DC Type II / AC Type III | DC Type II / AC Type III | DC Type II / AC Type III | |
| Certifications and Standards | Grid Regulation | IEC 61727/62116, EN50549-1 | IEC 61727/62116, EN50549-1 | IEC 61727/62116, EN50549-1 |
| EMC/Safety Regulation | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | |
| General Data | Operating Temperature Range(°C) | -40~60°C, >45°C Derating | -40~60°C, >45°C Derating | -40~60°C, >45°C Derating |
| Cooling | Smart cooling | Smart cooling | Smart cooling | |
| Noise(dB) | <50 dB | <50 dB | <50 dB | |
| Communication with BMS | RS485; CAN | RS485; CAN | RS485; CAN | |
| Monitoring mode | Wi-Fi+APP | Wi-Fi+APP | Wi-Fi+APP | |
| Weight(kg) | 19 | 19 | 24 | |
| Cabinet size(mm) (Excluding connectors) | 340W×520H×255D | 340W×520H×255D | 340W×610H×260D | |
| Ingress Protection Degree | IP66 | IP66 | IP66 | |
| Installation Style | Wall-mounted | Wall-mounted | Wall-mounted | |
| Warranty | 5 Years | 5 Years | 5 Years |
Installation and Monitoring
Plug and Play Monitoring Stay connected to your system anywhere in the world. The Xiensolar EP-D series comes with Wi-Fi + APP capability. Monitor your solar generation, battery levels, and load consumption in real-time. You can remotely adjust settings to prioritize “Self-Use” mode for savings or “Backup” mode for storm preparation.
Easy Installation Despite its heavy-duty performance, the unit is designed for easy wall-mounting. The connection terminals are easily accessible, and the setup via the LCD screen or App is intuitive for installers.
Frequently Asked Questions (FAQ)
Q: Does this 48V hybrid inverter UPS work without solar panels? A: Yes. It can function purely as a battery backup system. It will charge the batteries from the grid (AC) and provide UPS power during outages. You can add solar panels later.
Q: What is the noise level of the unit? A: The EP-D series uses smart active cooling to handle high power loads (especially the 190A charging). The noise level is less than 50dB, which is comparable to a quiet refrigerator or moderate rainfall. It is recommended for installation in utility rooms, garages, or outdoors.
Q: Can I use this with a generator? A: The system is designed primarily for Grid and PV inputs. However, it can work in off-grid setups. Please consult the manual regarding specific generator connection requirements and dry-contact settings.
Q: What batteries are compatible? A: It is compatible with most 48V Lead-Acid (AGM/Gel/Flooded) and Lithium-ion (LiFePO4) batteries. For Lithium batteries, we recommend brands that support CAN/RS485 communication for best performance.